Towers

 
NCRT
 
Motor control V1000
 
 

2019

Cable

The first thing to do is pulling the power cables thought the jacket pipe.

Using from PA1A stock pile, shielded 3x6mm VmVk-AS. For EMC noice and others this cable is required in combination with power-line-filtering

     
 


     
 

Testing

Workbench testing the 3x400VAC solid state relais and other equipment before compiling the motor drive.

 

     
       
 

Earth Shield

Aluminium plate above the components plate connecting all the ground wires and grounding for EMC purposes.

     
       
  Components

Yaskawa V1000 frequency controller, overvoltage protection, solid state relais and conventional 24VDC omron 4PDT relais.
     
       
 

Wiring

Using professional components and wiring.

     
       
 

Stock

Because I am a parts collector, all material is from stock.

     
       
  Testing

After wiring the unit has to be tested before install it in the housing.
     
  Cable lugs

Best way to assembling is using cable lugs to prevent release from the wires.
     
 


     
       
  Waterproofing

Drilled a hole in a plastic box and installed a 220VAC led, Using the water hose to check if this LED is waterproof (APPROVED)
     
     
  -->NEXT PAGE-->